AC DC Open Frame Type Power Supply 85W
MULTIPLE OUTPUT MODELS / OUTPUT CURRENT / AMPSOUTPUTDC OUTPUT (1)MINIMUMMAX (3)MAX (4)PEAK (4,5)V11.5 to 48V (7)0.5 (2)131719.5V21.5 to 48V (8)0.5 (2)38.59V31.5 to 48V (8)0.3 (2)355V41.5 to 48V (8)0.3
MULTIPLE OUTPUT MODELS / OUTPUT CURRENT / AMPS
OUTPUT | DC OUTPUT (1) | MINIMUM | MAX (3) | MAX (4) | PEAK (4,5) |
V1 | 1.5 to 48V (7) | 0.5 (2) | 13 | 17 | 19.5 |
V2 | 1.5 to 48V (8) | 0.5 (2) | 3 | 8.5 | 9 |
V3 | 1.5 to 48V (8) | 0.3 (2) | 3 | 5 | 5 |
V4 | 1.5 to 48V (8) | 0.3 (2) | 3 | 3.5 | 5 |
Input Specifications
Input Voltage:47-63 Hz; 90-264 VAC
Power Factor:Meets EN61000-3-2
Amendment 14
Inrush Current,115 VAC:35A P-P
Input Current:2.5A
Fusing:3.15A @ 250 VAC
Output Specifications
Continuous Output Power: | 85 Watts |
Line Regulation Over Input Range | |
V1-V4: | ±0.2% |
Load Regulation @ 60% ±40% | |
Full Load | |
- V1-V4: | ± 3% |
- V3-V4: | ± 5% max |
Cross Regulation @ 60% ±40% Full Load | |
- V1: | Change in V2-V4: ± 0.5% |
- V2-V4: | Change in V1 @75 ±25% F/L: ± 5% max |
Overvoltage Protection V1: | 130% Vout typ |
Overshoot, All Outputs: | 10% max |
Power Limit: | Set @120% typ |
Response Time: | 500 μSec |
Ripple & Noise @ 20 Mhz Band Width; | |
Full Load - All Outputs: | 1% P-P max |
Output Adjustment Range on V1: | 5% min |
General Specifications
Efficiency: | to 80% typ |
Switching Frequency: | 60KHz typ |
Susceptibility: | EN61000-4- 2;-3;-4;-5;-6;-8;-11 Level 3 |
Operating Temperature Range: | -20 to +70?C |
Minimum Start-up Temperature: | -20?C |
Derating from 50-70?C: | 2.5%/?C |
Storage Temperature: | -40 to +85?C |
Cooling: | See Note 5 |
Relative Humidity, | |
Non-Condensing: | 5-95% |
Cooling: | See Note 5 |
EMI: | FCC & VDE Class B; CISPR 22; EN 55022 Class B; EN55024 |
Vibration from 10-55Hz: | 1.0G Peak |